Screw Compressor CSHP - CSHP7593-110P
The new CSHP series is based on the proven design elements of the innovative BITZER compact screws, which are recognized as a benchmark around the world. The CSHP series has been specially developed for use in air cooled liquid chillers and heat pumps with the natural, low-GWP refrigerant propane (R290). Other hydrocarbon refrigerants may be used on request. Some characteristics of the CSHP series differ technically from those of the standard CSH series, including electrical accessories, safety devices, oil charge and the lubrication system. R290 is a flammable refrigerant of the A3 safety group. Special safety regulations apply to the design, operation and maintenance of refrigeration systems and heat pumps with flammable refrigerants. The CSHP series is available exclusively for OEM customers for use in series products.For more information, please see BITZER technical information KT-660 ‘Application of propane (R290) and propylene (R1270) with semi-hermetic compressors’.
- Adjustment of the internal volume ratio (under full- and part-load) based on the extended range of applications
- Reduction of internal flow losses
- Optimisation of the oil management system
- Additional cooling for extreme operating conditions through developed direct liquid injection or external oil cooling with actively controlled oil circulation level
Type | Displacement | Weight | Max. pressure (LP/HP) | Connection suction line | Connection discharge line | Oil type R290 | |
---|---|---|---|---|---|---|---|
2900 RPM 50 Hz | 3500 RPM 60 Hz | ||||||
SI | 336 m³/h | 406 m³/h | 555 kg | 19 / 28 bar | 76 mm - 3 1/8'' | 54 mm - 2 1/8'' | SHC230 (Standard) |
IP | 11866 CFH | 14321 CFH | 1224 lb | 275 / 400 psi | 76 mm - 3 1/8'' | 54 mm - 2 1/8'' | SHC230 (Standard) |
Extent of delivery (Standard)
Type | Enclosure class | Oil heater | Oil separator | Oil filter | Discharge gas temperature sensor | Start unloading | Capacity Control - 4-step | Capacity Control - infinite | Built-in check valve | Motor protection | Oil charge |
---|---|---|---|---|---|---|---|---|---|---|---|
SI | IP54 | 200 W (Standard) | Standard | Standard | Standard | Standard | 100-75-50-25% (Standard) | 100-25% (Standard) | Standard (FI) | SE-E1 (Standard), SE-E3(Standard for 660-690V) | 15,0 dm³ |
IP | IP54 | 200 W (Standard) | Standard | Standard | Standard | Standard (FI) | 100-75-50-25% (Standard) | 100-25% (Standard) | Standard | SE-E1 (Standard), SE-E3(Standard for 660-690V) | 527.9 fl oz |
Motor protection included for mounting in the system’s switch board
Available Options
Type | Oil level switch | Discharge shut-off valve | Suction shut-off valve | Shut-off valve for ECO with muffler | Liquid injection with integrated nozzle | Bridges for DOL start | Vibration dampers | Motor protection |
---|---|---|---|---|---|---|---|---|
SI | min / max OLC-D1-S (Option) | Option | Option | Option | Option | Option | Option | SE-i1 (200-690V) |
IP | min / max OLC-D1-S (Option) | Option | Option | Option | Option | Option | Option | SE-i1 (200-690V) |